The ideal Pressure sensor position for pulsation sensinf is that the sensor membrane is parallel with the flow and that the sensor extends through the near wall thermal and turbulent boundary layers. A wall flush position implies too high pressure measuement as the near wall boundary turbulence then is measured as well.

The ideal Pressure sensor position for pulsation sensinf is that the sensor membrane is parallel with the flow and that the sensor extends through the near wall
thermal and turbulent boundary layers. A wall flush position implies too high pressure measuement as the near wall boundary turbulence then is measured as well.